Wide Coverage Horizontal Ionizing Blower

Product Details
Customization: Available
Certification: CCC, ISO, RoHS
Usage: Combustible & Explosive Area, Computer Room, Electronic Component Maintenance Room, Printing Workshop, SMT Production Line
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2016-01-19
Registered Capital
1.48 Million USD
Management System Certification
ISO 9001
  • Wide Coverage Horizontal Ionizing Blower
  • Wide Coverage Horizontal Ionizing Blower
  • Wide Coverage Horizontal Ionizing Blower
  • Wide Coverage Horizontal Ionizing Blower
  • Wide Coverage Horizontal Ionizing Blower
  • Wide Coverage Horizontal Ionizing Blower
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SL-010
Model
SL-010
Operating Voltage
110V/60Hz or 220V/50Hz
Current Consumption
≤ 3.0 AMP of ≤ 1.5 AMP
Operating Temperature
32°f(0ºC)~122°f(0ºC)
Air Volume
45~190cfm
Air Coverage
60cm X 150cm
Weight
8.5kg
Transport Package
Carton
Specification
570mm (L) x220mm (W) x190mm (H)
Trademark
DR. SCHNEIDERPC
Origin
China
HS Code
8543709990
Production Capacity
2000sets Per Month

Product Description

Product Description

Cleanroom Ionizing Bench Top Blowers SL-010 is a static elimination device which delivers a balanced ion stream to neutralize wide, focused areas.

They remove contaminants attraction and neutralize static charges from wide, focused, or hard-to-reach areas so as to increase productivity In manufacturing.


They are ideally used in industrial environments such as delicate electronic products, electronic assembly line, medical device manufacturing and assembly lines, printing, packaging, and small part injection molding etc.
 

Ion balance voltage is ≤ +/-10V.
 

Detailed Photos
  • Rapid static elimination performance
Wide Coverage Horizontal Ionizing Blower
Wide Coverage Range:60cm x 150cmWide Coverage Horizontal Ionizing Blower
  • Uses AC technology to produce a inherently balanced output: ±10VWide Coverage Horizontal Ionizing Blower
  • Ionization status light
Wide Coverage Horizontal Ionizing Blower
Product Parameters
SL-010 Horizontal Electric Static Ionizing Air Blower
Model SL-010
Operating Voltage 110V/60Hz or 220V/50Hz
Consumption current ≤ 3.0 amp of ≤ 1.5 amp
Operating temperature 32°F(0ºC)~122°F(0ºC)
Air Volume 45~190CFM
Air Coverage 60cm x 150cm
Size 570mm (L) x220mm (W) x190mm (H)
Weight 8.5kg
Operating Voltage: 110V/220V,  Temperature: 22°c
Distance 300mm 600mm 900mm 1200mm
Left 300mm 1.5s 2.8s 3.9s 5.6s
Center 1.1s 2.2s 3.6s 5.9s
Right 300mm 1.4s 2.8s 3.8s 5.8s
 
Packaging & Shipping

ESD Shielding Bag Pack,Foam fixation, Carton Package.
Wide Coverage Horizontal Ionizing Blower

Company Profile

 

Xiamen Qianyu Technology Co., Ltd. is a reputable manufacturer specializing in Cleanroom Wipes, adhesive mats, adhesive rollers, ESD garments, ESD footwear, cleanroom swabs, catering to cleanroom facilities, construction sites, pharmaceutical sectors, ESD control industries, antibacterial environments, and other dust-free settings for over a decade.
Wide Coverage Horizontal Ionizing Blower

FAQ

Q: How does an ionizing air blower work?

A: An ionizing air blower works by generating ions that neutralize static charges on surfaces. It uses ionization technology to produce positive and negative ions, which are then blown onto the target area to eliminate static electricity

 

Q: What are the key technical specifications to consider when choosing an ionizing air blower?

A: When selecting an ionizing air blower, consider the following specifications: Input Voltage: Typically ranges from 100V to 240V AC. Output Voltage: High voltage outputs, often around ±4KV to ±7KV. Power Consumption: Varies by model, but generally low, with some models consuming less than 10W. Ion Balance: Maintains a balance within ±10V to ±30V. Discharge Speed: Fast discharge times, often less than 2.5 seconds. Airflow: Adjustable airflow up to 170 m³/hr (100 cfm) per fan. Noise Level: Low noise operation, typically between 45 dB and 56 dB. Operating Temperature: Suitable for a wide temperature range, usually from 0°C to 50°C. Humidity: Operates in environments with humidity levels up to 70% RH non-condensing.

 

Q: How do I maintain an ionizing air blower?

A: Regular maintenance is crucial for the effective operation of an ionizing air blower. Key maintenance tasks include: Cleaning the Emitter Tips: Regular cleaning of the emitter tips is necessary to ensure optimal performance. Some models feature automatic cleaning functions. Checking the Air Filters: Ensure that the air filters are clean and free from obstructions. Inspecting the Power Supply: Regularly check the power supply and connections for any signs of wear or damage.

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier